Sign In | Join Free | My burrillandco.com
Home > AI Ready Data Center >

CDUs AI Ready Data Center Cold Aisle Containment System Customized

    Buy cheap CDUs AI Ready Data Center Cold Aisle Containment System Customized from wholesalers
     
    Buy cheap CDUs AI Ready Data Center Cold Aisle Containment System Customized from wholesalers
    • Buy cheap CDUs AI Ready Data Center Cold Aisle Containment System Customized from wholesalers

    CDUs AI Ready Data Center Cold Aisle Containment System Customized

    Ask Lasest Price
    Brand Name : Soeteck
    Model Number : SYICDC40
    Certification : CE, ISO, UL
    Price : To Be Negotiated
    Payment Terms : D/A
    Supply Ability : 10000/Month
    Delivery Time : 5-10 Weeks
    • Product Details
    • Company Profile

    CDUs AI Ready Data Center Cold Aisle Containment System Customized

    AI training clusters and high-performance computing (HPC) systems push hardware to its thermal limits—standard data center cooling simply can’t keep up with the intense heat from dense GPU racks. The Customized CDU-integrated Cold Aisle Containment System for AI-Ready Data Centers is built specifically for this challenge, a purpose-designed solution that keeps critical AI hardware cool while adapting to the evolving cooling needs of next-gen LLM training and scientific computing.

    Unlike basic cold aisle containment, this AI-ready customized system supports hybrid cooling setups—seamlessly combining traditional precision air cooling with CDU-driven direct-to-chip liquid cooling as your GPU clusters grow. It’s engineered to handle the heavy weight and high heat output of AI servers, with reinforced structural support and purpose-built pathways for CDU coolant distribution. This 12-cabinet customized solution delivers the reliability mission-critical AI facilities need, serving as a stable foundation for scaling large language model training and high-density computing workloads.


    Product Family

    ConfigurationIT CabinetsPower / CabUPS SystemCooling CapacityRefrigeration TypeDimensions (L*W*H)
    Plan 1 12 Cabinets5 kW90K Rack Modular
    (15kVA modules, 4+1)
    25.5kW x 4
    (3+1 Redundancy)
    In-Row AC4800 x 3600 x 2000 mm
    Plan 2 12 Cabinets5 kW120K Tower Modular
    (30kVA modules, 3+1)
    65.5kW x 2
    (1+1 Redundant)
    In-Row AC4800 x 3600 x 2000 mm
    Plan 3 14 Cabinets5 kW120K Tower Modular
    (30kVA modules, 3+1)
    71.1kW x 1
    (N Redundancy)
    Room-Level AC4800 x 3600 x 2000 mm
    Plan 4 14 Cabinets5 kW120K Tower Modular
    (30kVA modules, 3+1)
    Custom Capacity
    (Tailored)
    FAN WALL4800 x 3600 x 2000 mm
    Plan 5 18 Cabinets5 kWModular N+1
    (25kVA modules, 4+1)
    31.1kW x 4
    (3+1 Redundancy)
    In-Row AC6000 x 3600 x 2000 mm
    Plan 6 24 Cabinets5 kWModular N+1
    (25kVA modules, 5+1)
    40.9kW x 4
    (3+1 Redundancy)
    In-Row AC8400 x 3600 x 2000 mm
    Custom ≤ 48 Cabinets≤ 15 kWMax 500kVA
    (2N/N+1 Redundancy)
    Flexible Capacity
    (Row or Room)
    Air / Water / ChilledLength ≤ 15000 mm

    Product Features

    AI Ready Data Center Cold Aisle Containment

    AI-Ready High-Density Infrastructure

    Powering Next-Gen Compute: Our infrastructure is engineered to handle the extreme thermal demands of Generative AI and Large Language Models (LLMs). By integrating dedicated liquid cooling manifolds and ultra-high-capacity power busbars, the system supports power densities exceeding 100kW per rack, ensuring your facility is ready for the latest GPU architectures.
    Seamless Scalability: Transition from traditional enterprise workloads to AI-intensive tasks without a full facility overhaul. Our modular design allows for the concurrent operation of air-cooled storage and liquid-cooled compute nodes, providing the flexibility to scale your AI capabilities as demand evolves.


    Architectural Adaptability & Hyperscale Power

    Limitless Flexibility: Unlike rigid standard modules, we customize aisle width, height, and length (up to 48 racks) to fit irregular room shapes or existing support pillars, maximizing whitespace utilization for dense AI clusters.
    Grid-Scale Power: Engineered with dual 400A+ busway inputs and 2N redundant Modular UPS systems to ensure uninterrupted power delivery for power-hungry AI training workloads and massive GPU clusters.

    CDUs AI Ready Data Center Cold Aisle Containment System

    AI Ready Data Center Cold Aisle Containment


    Focus on the core cooling demands of high-density data center deployments, where our full range of premium products leverages advanced technological advantages to reliably safeguard continuous, efficient, and stable operation.

    Cold Aisle Data Center

    5-30 kW per Cabinet

    Cold Aisle Data Center

    Airtight cold aisle enclosure, 90%+ cold air utilization rate, PUE ≤ 1.2, fast deployment and flexible expansion for medium-density IT loads.

    20ft Container Data Center

    10-80 kW Total Power

    20ft Container DC

    Prefabricated all-in-one design, anti-vibration & dust-proof, plug-and-play, ideal for edge computing and temporary computing demand scenarios.

    40ft Cold Plate Container Data Center

    30-100 kW per Cabinet

    40ft Cold Plate Container DC

    Hybrid air-liquid cooling, direct heat dissipation from GPU/CPU, AI-ready design, high power density with low energy consumption.

    40ft Immersion Cooling Container Data Center

    50-200 kW per Cabinet

    40ft Immersion Container DC

    Immersion cooling with dielectric fluid, 100x higher heat dissipation efficiency than air cooling, PUE ≤ 1.1, perfect for ultra-high density AI clusters.

    APPLICATIONS


    Empowering next-generation infrastructure with superior thermal management for high-wattage computing demands.

    AI Training and HPC Clusters
    AI Training & HPC Clusters
    High-Density Data Centers
    High-Density Data Centers
    Modular & Container Solutions
    Modular & Container Solutions
    Blockchain & Crypto Mining
    Blockchain & Crypto Mining

    FAQ


    1. What defines a data center as "AI-Ready"?
    An AI-Ready data center is engineered for extreme power density and thermal management. It features reinforced floor loading for heavy GPU clusters, high-voltage power distribution (such as 415V or 480V) to the rack, and a flexible cooling architecture capable of supporting 40kW to 100kW+ per cabinet.
    2. How does the infrastructure support high-performance networking (RDMA)?
    Our AI-Ready modules are designed with specialized overhead cable management systems to handle the high-density fiber counts required for InfiniBand and RoCE networks. We ensure optimized cable path lengths to minimize latency and maintain the strict bend radii necessary for 400G and 800G optical interconnects.
    3. Can your AI-Ready racks support liquid cooling for NVIDIA Blackwell or H100 systems?
    Yes. Our racks are pre-configured for liquid-to-chip cooling. They feature integrated manifolds and space for Coolant Distribution Units (CDUs), making them fully compatible with the high thermal design power (TDP) requirements of the latest NVIDIA Blackwell and Hopper architectures.
    4. How do you handle the massive power surges associated with AI training loads?
    AI workloads create highly variable power demands. Our solutions utilize intelligent PDUs and UPS systems with high-discharge batteries or flywheels that can handle rapid "step-loads," ensuring electrical stability even when thousands of GPUs ramp up to full power simultaneously.
    5. Are these modules scalable for rapid "Day 2" expansions?
    Absolutely. We use a modular "building block" design. You can start with a few high-density AI pods and add more as your compute needs grow. The cooling and power hookups are standardized for rapid deployment, reducing the "Ready-for-Service" time by up to 30% compared to traditional builds.
    6. What is the maximum rack weight capacity for fully loaded AI servers?
    Our AI-specific cabinets are built with heavy-gauge reinforced steel, supporting a static load rating of up to 2,200kg (approx. 4,850 lbs). This safely accommodates full-stack AI configurations, including internal bus bars, liquid manifolds, and multi-node GPU systems.
    7. How does AI-readiness impact the sustainability (PUE) of the facility?
    AI-Ready centers actually improve efficiency by moving cooling closer to the heat source. By utilizing Rear Door Heat Exchangers (RDHx) or Direct Liquid Cooling (DLC), we can remove heat more efficiently than traditional air-only methods, targeting a PUE of 1.12 or lower even at 100kW per rack densities.

    Have more questions about our Liquid Cooling Solutions?

    Contact Us Now
    Quality CDUs AI Ready Data Center Cold Aisle Containment System Customized for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: HEFEI SHUYI DIGITAL POWER CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)